Step 2: Up and Running
IN THIS SECTION
Set Parameter Values | 4
Perform the Initial Configuration | 4
Set Parameter Values
You must perform the initial configuration of the switch through the console port. Before you begin, set the following
parameter values in the console server or PC:
Baud Rate—9600
Flow Control—None
Data—8
Parity—None
Stop Bits—1
DCD State—Disregard
Perform the Initial Configuration
To connect and configure the switch from the console:
1. Connect the console port to a laptop or PC using the provided RJ-45 cable and RJ-45 to DB-9 serial port adapter. The
console (CON) port is located on the port panel of the router.
2. Log in as root. There is no password. If the software booted before you connected to the console port, you might need
to press the Enter key for the prompt to appear.
login: root
3. Start the command-line interface (CLI).
root@% cli
4