Grounding the SRX100 Services Gateway
To meet safety and electromagnetic interference (EMI) requirements and to ensure
proper operation, the SRX100 Services Gateway must be adequately grounded before
power is connected.
Figure 1 illustrates how a grounding cable connects to the services gateway.
Figure 1: Grounding the SRX100 Services Gateway
You ground the device by connecting a grounding cable to earth ground and then
attaching it to the chassis grounding points using one M3 screw.
CAUTION: Before device installation begins, a licensed electrician must attach a cable
lug to the grounding and power cables that you use. A cable with an incorrectly
attached lug can damage the device (for example, by causing a short circuit).
Table 1 lists the grounding components of the SRX100 Services Gateway.
Table 1: SRX100 Services Gateway Grounding Components
ComponentNumber
Grounding point on the chassis1
Grounding lug2
Grounding screw (M3 screw)3
Table 2 lists the specifications of the grounding cable used with the device.
Grounding the SRX100 Services Gateway 1

Other manuals for Juniper SRX100

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Juniper SRX100 and is the answer not in the manual?

Juniper SRX100 Specifications

General IconGeneral
Routing protocolsBGP, IS-IS, MPLS, OSPF
Switching protocolsVLAN 802.1Q, 802.3ad/LACP, STP
Supported network protocolsIPv4, IPv6, CLNS
Firewall securityYes
Security algorithms3DES, DES
Authentication methodRADIUS, RSA SecureID, LDAP
VPN supportIPsec VPN
Data transfer rate0.1 Gbit/s
Input voltage100 - 240 V
Input frequency50/60 Hz
Heat dissipation35 BTU/h
Power requirements100-240, 50/60
Power over Ethernet (PoE)No
Power consumption (typical)30 W
SafetyUL 60950-1, CSA 60950-1, AS / NZS 60950-1, AS / NZS 60950-1, CB Scheme, EN 60950-1
CertificationFCC Class B ICES class B AS / NZS CISPR22 Class B AS / NZS CISPR22 Class B VCCI Class B EN 55022 Class B, EN 300386
Mounting typeRack mounting
Internal memory1024 MB
Storage temperature (T-T)-20 - 70 °C
Operating temperature (T-T)0 - 40 °C
Weight and Dimensions IconWeight and Dimensions
Weight1100 g
Dimensions (WxDxH)216 x 147 x 36 mm