PROBLEMS
THE VACUUM PUMP OVERHEATS
Cause
Solution
• Insufficient or absent lubrication
• Verify oil and rings. Check oil pump efficiency
• Low tank oil level
• Fill tank with oil
• Excessive rotation speed
• Reduce rpm to the prescribed working speed
• Prolonged functioning at max vacuum rate
• Reduce vacuum rate
Insufficient cooling
Check oil pump efficiency. Bleed the system with care. Check heat exchanger
efficiency
Vacuum and/or exhaust line of insufficient diameter
Check dimensioning
THE VACUUM PUMP DOES NOT ROTATE
Cause
Solution
• Broken vanes:
• Clean inner chambers, replace vanes
- due to infiltrated solids
• Check the secondary shutoff and filters of the suction line
- due to insufficient lubrication
• Check the oil pump
• Power transmission breakdown
• Check and replace the damaged parts
• Ice inside the pump (during the cold season)
• Remove ice and slowly start running it. Avoid suction of water
REDUCED PERFORMANCES
Cause
Solution
• Four way changeover valve in idle position
• Move the lever to vacuum or pressure mode end stroke
• Four way changeover valve not correctly registered
• Adjust the functioning play and lubricate
• Worn vanes
• Replace vanes
• The non-return valve leaks
• Clean or replace if necessary
• Worn seal rings
• Replace
• Tank gate valves or gaskets leak
• Replace damaged or worn parts
• Tank connection pipes leak or are obstructed
• Replace damaged pipes
• Obstructed primary shutoff or suction filter
• Remove and clean
• Encrusted exhaust port
• Remove and clean
• Vacuum line components are too small dimensioned
• Verify dimensions for pump maximum performances
• Obstructed rubber couplings
• Replace
UNUSUAL OIL CONSUMPTION
Cause
Solution
• Insufficient or absent lubrication
• Check and adjust the lubricating pump
Recycling materials allow reducing the environmental impact and
respecting the environment.
Before scrapping the machine, the following materials need to be
separated and suitably disposed of:
Do not dispose of in the environment. Dispose of
in compliance with the standards in force.
Material
Cast Iron
Steel
Alluminum
Copper
Bronze
Rubber
Vane
Oil
Gasket
Plastic
LC 300
83,1 %
12,4 %
0,7 %
0,2 %
0,2 %
0,1 %
0,6 %
2,1 %
0,1 %
0,4 %
LC 420
89,0 %
8,0 %
0,6 %
0,2 %
0,1 %
0,1 %
0,8 %
0,5 %
0,4 %
0,2 %
LC 580
88,0 %
9,0 %
0,5 %
0,2 %
0,1 %
0,1 %
0,9 %
0,4 %
0,4 %
0,2 %
LC 750
93,0 %
5,0 %
0,4 %
0,2 %
0,1 %
0,1 %
0,6 %
0,3 %
0,3 %
0,2 %
8. Scrapping