(No.YA369)1-17
4.6 INITIAL SETTING VALUES IN THE SERVICE MODE
• Perform fine-tuning based on the "initial values" using the remote control when in the Service mode.
• The "initial values" serve only as an indication rough standard and therefore the values with which optimal display can be achieved
may be different from the default values. But, don't change the values that are not written in "ADJUSTMENT PROCEDURE". They
are fixed values.
4.6.1 ADJUSTMENT MODE
4.6.1.1 VIDEO SYSTEM SETTING -1 4.6.1.2 VIDEO SYSTEM SETTING -2 (Fixed values)
4.6.1.3 AUDIO SYSTEM SETTING (Fixed values)
4.6.1.4 VIDEO SYSTEM SETTING -3 (Fixed values)
Item No. Item name Variable range Setting value
S001 5I R OF 000 - 255 127
S002 5I G OF 000 - 255 127
S003 5I B OF 000 - 255 126
S004 5P R OF 000 - 255 127
S005 5P G OF 000 - 255 127
S006 5P B OF 000 - 255 126
S007 HD75 R OF 000 - 255 127
S008 HD75 G OF 000 - 255 127
S009 HD75 B OF 000 - 255 126
S010 HD25 R OF 000 - 255 127
S011 HD25 G OF 000 - 255 127
S012 HD25 B OF 000 - 255 126
S013 R DRIVE 000 - 255 150
S014 G DRIVE 000 - 255 126
S015 B DRIVE 000 - 255 117
S016 HD R DR -32 - 31 00
S017 HD G DR -32 - 31 00
S018 HD B DR -32 - 31 00
S019 CL R DR -32 - 31 01
S020 CL G DR -32 - 31 01
S021 CL B DR -32 - 31 08
S022 WM R DR -32 - 31 00
S023 WM G DR -32 - 31 -7
S024 WM B DR -32 - 31 -16
S025 HD CL R DR -32 - 31 01
S026 HD CL G DR -32 - 31 00
S027 HD CL B DR -32 - 31 00
S028 HD WM R DR -32 - 31 00
S029 HD WM G DR -32 - 31 -2
S030 HD WM B DR -32 - 31 -1
S031 PC R OF 000 - 255 115
S032 PC G OF 000 - 255 127
S033 PC B OF 000 - 255 127
S034 PC R DR -32 - 31 -23
S035 PC G DR -32 - 31 00
S036 PC B DR -32 - 31 00
S037 PC CL R DR -32 - 31 00
S038 PC CL G DR -32 - 31 03
S039 PC CL B DR -32 - 31 09
S040 PC WM R DR -32 - 31 00
S041 PC WM G DR -32 - 31 -6
S042 PC WM B DR -32 - 31 -15
S043 PC AUTO WB 0 - 1 0
Item No. Item name Variable range Setting value
M001 MV CON 000 - 255 105
M002 MV SHA 00 - 63 09
M003 MV COL 000 - 255 147
M004 MV TIN 000 - 255 051
M005 AGC GAIN 000 - 255 120
M006 ERR Limit 000 - 127 022
M007 PC R GAIN 000 - 255 099
M008 PC G GAIN 000 - 255 099
M009 PC B GAIN 000 - 255 101
Item No. Item name Variable range Setting value
A001 S BASS 00 - 16 8
A002 S TRE 00 - 16 8
A003 3D LEVEL 00 - 63 31
Item No. Item name Variable range Setting value
D001 S CON 00 - 63 20
D002 S BRI 00 - 63 47
D003 S SHA 00 - 15 0
D004 S COL 00 - 63 35
D005 S TIN 00 - 63 32
D006 RGB S COL 000 - 127 085
D007 5I S CON 00 - 63 25
D008 5I S BRI 00 - 63 35
D009 5I S SHA 00 - 63 46
D010 5I S COL 00 - 63 53
D011 5I S TIN 00 - 63 35
D012 5P S CON 00 - 63 24
D013 5P S BRI 00 - 63 35
D014 5P S SHA 00 - 63 18
D015 5P S COL 00 - 63 51
D016 5P S TIN 00 - 63 35
D017 HD75 S CON 00 - 63 29
D018 HD75 S BRI 00 - 63 32
D019 HD75 S SHA 00 - 63 30
D020 HD75 S COL 00 - 63 52
D021 HD75 S TIN 00 - 63 34
D022 HD25 S CON 00 - 63 29
D023 HD25 S BRI 00 - 63 32
D024 HD25 S SHA 00 - 63 30
D025 HD25 S COL 00 - 63 52
D026 HD25 S TIN 00 - 63 34