OC stands for Over Current; DT/SD stands for Dead
Time and Shut Down.
The DT (dead time) is defined as the time period from the
starting point of turn-off on one side of the switching
stage to the starting point of turn-on on the other side.
DT/SD pin provides two functions: 1) setting deadtime
and 2) shutdown. There are 4 modes of DT pre-
programmed in IC.
The IRS20124 determines its operation mode based on
the voltage applied to the DT/SD pin. An internal
comparator translates which mode is being used by
comparing internal reference voltages.
Since IRS20124 has internal dead time generation, if
independent inputs for HO and LO are no longer
provided; shutdown mode is the only way to turn off
both MOSFETs simultaneously to protect them from over
current conditions.