4000 Programmable Electronic Pushbutton Lock
4000 Programmable Electronic Pushbutton Lock • PK2971
Page 14
2.5 Manual Programming Reference Chart
Command Name
Disable Users 0
00 # ALL codes (except Master)
0M # Manager of group M (from 1 to 6)
G0 # All users in group G (from 1 to 6) YES
GU # User U (from 1 to 9) in group G (from 1 to 6) YES
77 # Service access code YES
Activate Users 1
00 # ALL codes (except Master)
0M # Manager of group M (from 1 to 6)
G0 # All users in group G (from 1 to 6) YES
GU # User U (from 1 to 9) in group G (from 1 to 6) YES
77 # Service access code YES
Add/Modify Users 2 0M # Manager of group M (from 1 to 6)
KKKKKKK # Enter 7-digit code
GU # User U (from 1 to 9) in group G (from 1 to 6)
KKK{KKK} # Enter 3 to 6-digit code, same length as all
other access codes YES
77 # Service access code
KKK{KKK} # Enter 3 to 6-digit code, same length as all
other access codes YES
99 # Master authorization code
MMMMMMM Enter 8-digit code
M # Re-enter 8-digit code to confirm
MMMMMMMM #
Delete Users 3
00 # ALL codes (except Master)
0M # Manager of group M (from 1 to 6)
G0 # All users in group G (from 1 to 6) YES
GU # User U (from 1 to 9) in group G (from 1 to 6) YES
77 # Service access code YES
Passage Mode 4
00 # OFF (normal operation) YES
01 # ON (no code required to open door) YES
Lock-out Mode 4 90 # OFF (normal operation) YES
91 # ON (all user access codes temporarily locked out,
YES
Master and Manager codes still accepted for
programming)
Unlock Time Setup 5 SS # Select from 01 to 20 seconds to turn the handle
after entering a valid code
Tamper Parameters Setup 6
MM # Shutdown period, from 00 to 15; 00 = 30 sec,
1 to 15 = minutes
9N #
Tamper counter, from 3 to 6 invalid codes
prior to shutdown
Buzzer Volume Setup 7
00 # OFF
0N # Volume level control, from 1 to 9
Configuration Setup 8
00 # Commercial configuration
01 # Residential configuration
02 # Handicapped configuration
Manual Diagnostics 9 30 # Start Manual Diagnostics
123456789*0 Press each key in sequence to test the keypad.a
#
Passage Mode with Timer 9 41 # Set timer for HH = 1 to 24 hours, 99 = no time limit.
HH # The lock will enter Passage Mode immediately and return
to locked mode (normal operation) after the timer has elapsed. YES
Privileged User Setup
9 5G # Set all users in group G (from 1 to 6) as privileged YES
9 6G # Set all users in group G (from 1 to 6) as normal YES
Factory Defaults 9 99 # Restore factory default settings, erases all codes except
the Master code
Command
(1
st
digit)
Arguments
(2
nd
& 3
rd
digit )
Description Available
to group
Manager