EasyManua.ls Logo

Kaleidescape Strato - Physical Installation; Ventilation and Clearance; Power Requirements; Network Requirements

Default Icon
41 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
9
Physical Installation
Planning the Installation
Ventilation and Clearance
Use the following guidelines when installing system components to ensure
proper clearance and ventilation. These guidelines apply to all installations
including rack mounting. (Rack-mount hardware sold separately.)
1. Mount components in a location with adequate ventilation.
2. Check for proper grounding if installing components in a rack.
3. Maintain a 2 in. (5 cm) clearance in back and a 1 in. (2.5 cm) clearance
in front and on the sides.
Power Requirements
Kaleidescape component power supplies are universal input and operate on
any nominal line voltage between 100240 V, and frequency between 5060
Hz. Verify that power outlets are grounded, preferably shielded from power
surges and brownouts.
Kaleidescape recommends a grounded outlet with a high-quality surge protector
for the power source for players and servers. A UPS is optional.
Network Requirements
A Gigabit Ethernet network is recommended, and is required when Strato is
used with any other Kaleidescape components. Connect Strato using a
shielded Ethernet cable. The built-in Wi-Fi may be used when Strato is used as
a single-component standalone system.
Audio and Video components
Before beginning the installation, determine the type of the display and
audio equipment that will connect to your Strato.
Strato supports the following outputs:
Video
u High-Definition Multimedia Interface (HDMI). HDMI 2.0 and HDCP 2.2
are required for 4K Ultra HD content. HDMI 2.0a is required for HDR.
Audio
u HDMI (Digital stereo or multi-channel)
u Coaxial (Digital stereo or multi-channel)
u Optical (Digital stereo or multi-channel)

Table of Contents