33
BEING USED TO ACHIEVE THE WINNING NUMBER. WHEN
SET TO 0 THE FUNCTION IS OFF. DEFAULT VALUE: 0 ā NO
HELP SCORING PRIZES.
P86
DEFINES FREQUENCY OF RESETTING HIGH SCORES -
TIME IN HOURS. AVAILABLE RANGE IS 0 TO 240. IF SET TO
0 THEN THE FUNCTION IS OFF. DEFAULT VALUE: 0.
NOTE:
THIS TIME IS CALCULATED FROM THE LAST RESETTING
EITHER AUTOMATIC OR MANUAL (USING THE DIP
SWITCH #4). WORKS WITH P87.
P87
DEFINES FOR HOW LONG (TIME IN MINUTES) MACHINE
NEEDS TO BE IN THE IDLE STATE (NOT OPERATED BUT
TURN ON) FOR THE SCORES TO BE RESET. THE LIMIT OF
HOURS IN P86 MUST BE FIRST MET. AVAILABLE RANGE IS
0 TO 240. IF SET TO 0 THEN THE FUNCTION IS OFF.
DEFAULT VALUE: 1. SET IT ALONG WITH P86.
P88
PARAMETER USED BY FACTORY.
P89
SURPRISE BALL (CAPSULE) DISPENSE SETUP FOR
WINNING THE PRIZE FROM WHEEL OF FUN/ FORTUNE
FUN (WHEN P11 = 2 AND P23 = 1 OR P23 = 2). RANGE 0-7,
DEFAULT SETTING IS 0.
P89 value
0 OFF OFF OFF
1 ON OFF OFF
2 OFF ON OFF
3 ON ON OFF
4 OFF OFF ON
5 ON OFF ON
6 OFF ON ON
7 ON ON ON
- Example: when P89 is set to 5 then the ball will be dispensed
only if the player wins prize #3 or prize #1. Winning prize #2
will not trigger the ball dispenser.