P81
RELAX – TIME FOR WHICH HALOGEN LAMP WILL BE ON
(RANGE 0-5 SECONDS), JUMP 0.1 SECOND).
P81=0.0 - THE FUNCTION IS OFF, HALOGEN WILL NOT
SHINE.
P81=0.1...5.0 - HALOGEN SHINES.
- Example: when P81=0.4 it means the halogen lamp will be ON for
0.4 second.
DEFAULT SETTING IS 0.0 – RELAX FUNCTION IS OFF.
P82
RELAX – DEFINES FREQUENCY OF HOW OFTEN HALOGEN
LAMP WILL NOT SHINE (RANGE 1 SECOND TO 1 HOUR).
TIME IS GIVEN IN FOLLOWING FORMAT: HH.MM.SS.
P82=00.00.01...00.00.10 (1 TO 10 SECONDS, 1 SECOND JUMP),
P82=00.00.10...00.10.00 (10 SECONDS TO 10 MINUTES, 5
SECONDS JUMP),
P82=00.10.00...01.00.00 (10 MINUTES TO 1 HOUR, 1 MINUTE
JUMP).
DEFAULT SETTING IS P82=00.00.30 (30 SECONDS).
- Example: when P82 is set to 10, every 10 seconds halogen will not
shine (pause).
IMPORTANT:
P82 CAN BE SET BUT IT ALWAYS HAS TO BE EQUAL OR
HIGHER VALUE THAN P81.
- Example: setting P81=4.5 and P82 00.00.01 cannot be done.
P83
NOT USED.
P84
DEFINES HOW MANY CREDITS NEED TO BE RECEIVED BY
THE MACHINE IN ORDER TO ACTIVATE ASSISTING
FUNCTION SET IN P85 AND TO DISPENSE CAPSULE (RANGE
0-999, DEFAULT VALUE 0). WHEN SET TO 0 THE FUNCTION
IS OFF (CAPSULES FOR MULTIPLES OF 100 AND TRIPLE
NUMBERS WILL BE DISPENSED). WHEN CREDIT COUNT IS
SMALLER THAN P84, NO CAPSULE WILL BE DISPENSED.
WHEN CREDIT COUNT IS BIGGER THAN P84, THE CAPSULES
FOR MULTIPLES OF 100 OR TRIPLE NUMBERS WILL BE
DISPENSED.