TXFlow ON|OFF default OFF
When ON,
XFlow
is used to determine the type of flow control used during Transparent Mode.
When OFF, software flow control is not used, i.e.,
XFlow
is treated as OFF. If
TXFlow
and
XFlow
are
both ON, the KAM will use the XON and XOFF characters to control input from the terminal.
Unproto call 1(VIA call2, call 3....call5) default CQ/CQ
This command is used to set the digipeat and destination address fields of packets sent in the
unconnected mode. Unconnected packets are sent as unsequenced I-frames with the destination
and digipeat fields taken from call 1 through call 5. Unconnected packets sent from other units can
be monitored by setting
Monitor
ON and setting
BUdlist
appropriately. The digipeater list is also
used for BEACON packets (which are sent to destination address BEACON). If
Unproto
is "NONE",
no unconnected packets will be sent except for BEACON and ID.
USers
n
default 1/1
n
may be set to any value between 0 and 26. This command specifies the channels which may
be available to incoming connect requests. For example, if
USers
=
5
then an incoming connect re-
quest will connect to the lowest channel A-E, if any of these channels are in the unconnected
state. If none of the 5 channels are available, a DM packet will be sent back to the requesting sta-
tion and the message connect request:(call) will be output to your terminal. If
USers
is set
to 0 no one will be able to connect to you. If
USers
is set higher than
MAXUsers
, the extra is
ignored.
USOs ON|OFF default ON
When ON, an unshift to letters case is effected when a space is received in BAUDOT RTTY. If
LCRtty
is ON, a space will cause an unshift to lower case.
Xflow ON|OFF default OFF
When
Xflow
is ON, the device connected to the terminal port is assumed to respond to flow
control characters XON and XOFF. When
Xflow
is OFF, the unit will only respond to hardware flow
control lines CTS and RTS.
XMitecho ON|OFF default OFF
When ON, characters are echoed when they are sent to the transceiver for output. When OFF,
echo is immediate.
XOff
n
default $13 (CTRL-S)
This command selects the character sent by the unit to the terminal to stop input from that de-
vice.
XON
n
default $11 (CTRL-Q)
This command selects the character sent by the unit to the terminal to restart input from that