EasyManuals Logo

Kärcher BP 3 Home User Manual

Kärcher BP 3 Home
15 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #8 background imageLoading...
Page #8 background image
– 4
Troubleshooting
DANGER
To avoid risks, all repairs and replacement of spare parts may only be carried out by authorized customer service
personnel.
First pull out the plug from the mains before carrying out any tasks on the machine.
Fault Cause Remedy
Pump runs but does
not transport
Air in the pump see chapter “Preparing the Appliance”
Air does not come out on the pressure
side
Open tap on pressure side
No water available. Check the water reservoir.
Pump does not run or
suddenly comes to a
standstill during oper-
ations
Power supply interrupted Check fuses and electrical connections
Thermal protection switch in the motor
has switched off the pump as it was over-
heated.
Pull out the mains plug, let the pump cool down,
clean the suction area, prevent dry running
Note
The cooling down time until the motor starts up
again can be up to 150 min.
Pump switches itself
off and back on
Thermal protection fuse has switched the
pump off to protect from overheating or
turned it back on after it has cooled off.
In order to prevent a repetition, the system should
be checked for leaks and sealed.
Motor starts up imme-
diately after switch off
Pressure is not retained in the system Check connections including sealings and control
the water outlet.
The smallest of leakages can affect the operation
adversely.
Air pressure in the storage boiler is too
low.
Fill storage boiler with 2.0 bar. See chapter “Main-
tenance”
Backflow valve does not close properly Check backflow valve on suction side.
Membrane in pressure tank is defective Replace membrane
Pump transports is re-
ducing or transported
quantity is too low
Suction filter or check valve (special ac-
cessories) contaminated
Clean suction filter or check valve (special acces-
sories)
The quantity transported by the pump de-
pends on the transport height and the
connected periphery
Keep max. flow height, see technical data. If nec-
essary, select a different hose diameter or hose
length.
Vibrating sound while
taking out water
Membrane in pressure tank vibrates Noise caused by operations and the noise can be
reduced by reducing the pressure in the air filling of
the storage tank.
Our Kärcher branch will be pleased to help you further in the case of questions or faults. See address on the reverse.
13EN
Ташев-Галвинг ООД
www.tashev-galving.com

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kärcher BP 3 Home and is the answer not in the manual?

Kärcher BP 3 Home Specifications

General IconGeneral
TypeBooster pump
Proper useWater purification
Product colorBlack, Yellow
Housing materialStainless steel
Suitable for indoor useYes
Suitable for outdoor use-
Flow rate3000 l/h
Maximum suction height7 m
Maximum delivery height36 m
Maximum operating pressure3.6 bar
Maximum input water temperature35 °C
Power cable typeH05RN-F
Power source typeAC
Cable length1 m
Connecting thread typeG1
Weight and Dimensions IconWeight and Dimensions
Depth450 mm
Width270 mm
Height550 mm
Weight11300 g

Related product manuals