EasyManua.ls Logo

Kärcher BPP 3000/42 - Troubleshooting Guide; Pump Fails to Transport Fluid; Pump Not Running or Stops Intermittently

Kärcher BPP 3000/42
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
– 6
6.997-359.0 Pump connection
piece G1 (33.3 mm)
Suitable for 3/4“ (19 mm) or 1“ (25.4 mm) hoses.
With G1“ (33.3 mm) threaded connection. Including
backflow valve, flat seal and hose clamp. If used for
garden pumps, install the flat seal.
6.997-358.0 Connection kit Basic
G1 (33.3 mm)
To connect 1/2“ (12.7 mm) water hoses to pumps
with G1 (33.3 mm) threaded connections.
6.997-340.0 Connection kit Pre-
mium G1(33.3 mm)
To connect 3/4“ (25.4mm) water hoses to pumps
with G1 (33.3 mm) threaded connections. For in-
creased water flow.
6.997-356.0 Swimmer switch Switches the pump on and off automatically de-
pending on the water level in the water tank. With
10 m special connection cable.
6.997-355.0 Dry run fuse If no more water flows through the pump, the dry
run fuse will protect the pump from damage and au-
tomatically turn it off. With G1“ (33.3 mm) threaded
connection.
6.997-417.0 Pressure compen-
sating hose 3/4“
(19mm), 1m
Connecting hose for the pressure compensation in
the domestic water supply system. To connect the
pump to rigid pipe line systems. Furthermore, the
internal storage volume in the hose prevents fre-
quent switching on and off of the pump.
Troubleshooting
Danger
To avoid risks, all repairs and replacement of spare parts may only be carried out by au-
thorized customer service personnel.
First pull out the plug from the mains before carrying out any tasks on the machine.
Fault Cause Remedy
Pump runs but
does not trans-
port
Air in the pump Refer to Chapter "Preparation" Figure
E
Air does not come out on the
pressure side
Open tap on pressure side
Pump does not
run or suddenly
comes to a
standstill during
operations
Power supply interrupted Check fuses and electrical connec-
tions
Thermal protection switch in
the motor has switched off the
pump as it was overheated.
Pull out the mains plug, let the pump
cool down, clean the suction area,
prevent dry running
18 EN