Loading...
– 8
Technical specifications
BPP
3000/42
BPP
4000/48
BPP
4500/50
Voltage V 230 - 240 230 - 240 230 - 240
Frequency Hz 50 50 50
Output P
nom
W 700 900 1200
Max. flow rate l/h 3000 3700 4500
Max. Suction height m 8 8 8
Max. pump pressure MPa
(bar)
0,40
(4,0)
0,43
(4,3)
0,50
(5,0)
Working pressure MPa
(bar)
0,17 - 0,28
(1,7 - 2,8)
0,17 - 0,30
(1,7 - 3,0)
0,17 - 0,32
(1,7 - 3,2)
Max. air pressure in the storage tank MPa
(bar)
0,18 - 0,2
(1,8 - 2,0)
0,18 - 0,2
(1,8 - 2,0)
0,18 - 0,2
(1,8 - 2,0)
Max. permissible internal pressure in
the storage tank
MPa
(bar)
0,50
(5,0)
0,50
(5,0)
0,50
(5,0)
Weight kg 16 16 17
Subject to technical modifications!
Operating pressure and transported quantity depends on the suction height and
the connected periphery!
The possible feed volume is even larger:
- the lower the suction and flow heights
- the larger the diameter of the hoses used
- the shorter the hoses used are
- the lower the pressure loss caused by the connected accessories
20 EN