5. When cleaning work is finished, release the trigger and turn the switch to “OFF/O
position and then turn off the water supply.
Observation: When not in use, make sure the gun lock switch is in the “Locked
position.
Observation: Using the high pressure washer after the water supply has been turned
off can cause serious damage to the pump and/or motor.
Warning: Never disconnect the high pressure hose from the machine while the
system is pressurized. To depressurize, turn off the machine, then turn off the
water supply and press the gun trigger 2-3 times.
6. Disconnect the power cord from the outlet.
Warning: It is recommended to use a residual current device (residual differential
switch - DR) that interrupts the power supply if the ground leakage current exceeds 30
mA for 30 ms, or a ground circuit fault device.
Warning: It is recommended to use a maximum 16A slow-acting circuit breaker.
INFORMAÇÕES PARA USO
USAGE INFORMATION
1. Safety valve and/or pressure limiting valve
Warning ‒ Danger!
Do not modify or adjust the safety valve settings.
The safety valve is also a pressure limiting valve. When the gun trigger is released, the
valve opens, the pressure switch is actuated and the machine automatically shuts off.
If the gun nozzle is blocked, the pressure in the machine will increase, the safety valve
will open, the pressure switch will operate and the machine will automatically shut
down. See below how to use a needle to clean the nozzle.