Read this manual carefully before installing or operating your new air conditioning
unit. Make sure to save this manual for future reference.
OWNER'S MANUAL
Duct A6 Type
KPD-35 DVN12
KPD-52 DVN12
KPD-71 DVN11
KPD-90 DVN12
KPD-105 DVN11
KPD-105 DTN11
KPD-140 DVN11
KPD-140 DTN11
KPD-160 DTN11
KPD-35 DVR12
KPD-52 DVR12
KPD-71 DVR11
KPD-90 DVR12
KPD-105 DVR11
KPD-105 DTR11
KPD-125 DVR12
KPD-140 DTR11
KPD-160 DTR11

Questions and Answers

  • W
    whitakerkimberlyAug 4, 2025
    Why is my Kaysun Air Conditioner not working?
    • S
      samanthasalazarAug 4, 2025
      Your Kaysun Air Conditioner might not be working due to several reasons: a power failure (wait for the power to be restored), the power switch being off (turn the power on), a burned-out fuse (replace the fuse), dead remote control batteries (replace the batteries), or the unit's 3-minute protection being activated (wait three minutes after restarting the unit).
  • T
    Tami KnappAug 18, 2025
    What to do if my Kaysun KPD-35 DVN12 Air Conditioner starts and stops frequently?
    • B
      Brandon PenaAug 18, 2025
      If your Kaysun Air Conditioner starts and stops frequently, it could be due to too much or too little refrigerant in the system (check for leaks and recharge the system with refrigerant), the presence of air, incompressible gas, or foreign material in the refrigeration system (evacuate and recharge the system with refrigerant), a blocked system circuit (determine which circuit is blocked and replace the malfunctioning piece of equipment), a broken compressor (replace the compressor), or voltage that is too high or too low (install a manostat to regulate the voltage).
  • J
    jonessherriAug 27, 2025
    Why is my Kaysun KPD-35 DVN12 heating poorly?
    • C
      Cody LewisAug 27, 2025
      Poor heating performance in your Kaysun Air Conditioner can occur if the outdoor temperature is lower than 7ºC (44.5ºF) (check for leaks and recharge the system with refrigerant). Cold air entering through doors and windows (make sure that all doors and windows are closed during use) or low refrigerant due to a leak or long-term use (check for leaks, re-seal if necessary and top off refrigerant) may also be the cause.
  • C
    Christina GarciaNov 11, 2025
    Why is my Kaysun KPD-35 DVN12 Air Conditioner cooling poorly?
    • D
      Dylan WhiteNov 11, 2025
      Poor cooling performance in your Kaysun Air Conditioner can stem from several causes. The temperature setting might be higher than the ambient room temperature (lower the temperature setting). The heat exchanger on either the indoor or outdoor unit could be dirty (clean the affected heat exchanger). The air filter may be dirty (remove and clean the filter according to instructions). The air inlet or outlet of either unit might be blocked (turn the unit off, remove the obstruction, and turn it back on). Open doors and windows can also affect cooling (ensure all doors and windows are closed). Excessive heat generated by sunlight (close windows and curtains during periods of high heat or bright sunshine) or low refrigerant levels due to leaks or long-term use (check for leaks, reseal if neces...

Summary

Safety Precautions

General Safety Symbols

Explains the meaning of warning and caution symbols for user safety.

Installation & Operation Safety

Critical safety measures for installation and operation to prevent injury.

R-32 Refrigerant Safety

Specific safety guidelines for R-32 refrigerant usage and handling.

Indoor Unit Parts and Major Functions

Unit Parts Overview

Diagram illustrating the components of the indoor unit.

Operating Conditions

Defines temperature ranges for safe and effective cooling, heating, and dry modes.

Unit Features

Details on default settings, auto-restart, louver memory, and leak detection systems.

Energy Saving Tips

Recommendations for efficient operation and energy conservation.

Manual Operations

Indoor Unit Control Panel

Description of the indoor unit's control panel and its indicators.

Manual Button Operations

Explanation of the manual button functions: AUTO, FORCED COOL, and OFF modes.

Care and Maintenance

Maintenance Safety Precautions

Safety warnings related to cleaning, repair, and electrical hazards.

Unit Cleaning

Instructions for cleaning the indoor unit using appropriate methods.

Air Filter Cleaning

Guidance on how to clean or replace the air filter for optimal efficiency.

Refrigerant Leak Handling

Procedures for responding to refrigerant leaks and system detection.

Preparation for Non-Use

Steps for storing the unit during extended periods of non-use.

Troubleshooting

General Cautionary Actions

Actions to take when specific abnormal conditions occur.

Common Operational Issues

Identifies common problems and their possible causes for normal operation.

Troubleshooting Tips

Solutions for common problems like unit not working, poor cooling, or frequent stops.

Error Codes

List of error codes, their causes, and indicator status for diagnosis.

European Disposal Guidelines

Disposal Options

Information on proper disposal methods for the appliance in European countries.

Environmental Warning

Highlights the environmental impact of improper disposal.