Unit: meter per second
Value range: 0.000...0.300 m/s
Factory setting: 0.000 m/s
Adjusted value: approx. 0,02 m/s
- To improve the positioning the set speed change occurs without
jerk limit.
- If the correction speed is selected for the actual set speed it is not
possible to switch onto a higher set speed.
Operating Frequency
Change
Using parameter LF.38 (operating frequency) you can set, whether
the operating frequency should constantly be 8 kHz or whether the
automatic transfer should be activated.
Unit: 1
Value range: 0 = operating frequency constantly 8 kHz
1 = automatic operating frequency change
Factory setting: 1
Adjusted value: as needed
8. Parameter Description
Set Value V
B
,
Correction Speed
Unit: meter per second
Value range: 0.000...LF.20
Factory setting: 0.000 m/s
Adjusted value: like LF.20 or smaller
Unit: meter per second
Value range: 0,000...0,300 m/s
Factory setting: 0,000 m/s
Adjustment value: approx. 0,1 m/s
If the display often shows the error message „E.OL2“
the adjustment
0= operating frequency constantly 8 kHz is
recommended.
Set Value V
E
,
Crawl Speed
If the crawl speed is selected for the actual set speed it is not possible
to switch onto a higher set speed.
Set Value V
N
,
Rated Speed
Unit: meter per second
Value range: 0.000...0,630 m/s
Factory setting: 0.000 m/s
Adjusted value: approx. 0,500 m/s
If the inspection speed is selected for the actual set speed it is not
possible to switch onto a higher set speed.
Set Value V
I
,
Inspection Speed