ANTRIEBSTECHNIK
GB 49
GB
Unit: 1
Value range: 0 … 65535
Factory setting: 70
Adjusted value: dependent on ratio of inverter / motor
SSM KI Speed
Unit: 1
Value range: 0 … 65535
Factory setting: 230
Adjusted value: dependent on ratio of inverter / motor
SSM KP Speed
Unit: 1
Value range: 0 … 65535
Factory setting: 625
Adjusted value: dependent on ratio of inverter / motor
SSM KP Current
For a better load transfer at high efficiency gears.
Unit: 1
Value range: 0 … 65535
Factory setting: 0
Adjusted value: dependent on ratio of inverter / motor and the
type of the gear
SSM KI Speed Offset
Unit: newtonmeter
Value range: 0,1 … 5 * motor rated torque
Factory setting: 1,5 * LF.A5
Adjusted value: according to loading case and motor
SSM Torque Maximum
Unit: 1
Value range: 0 … 65535
Factory setting: 70
Adjusted value: dependent on ratio of inverter / motor
SSM KI Current
8. Parameter Description
Unit: 1
Value range: 0 … 7
Factory setting: 0
Adjusted value: 0 Position trimming off
1 Position trimming started