After charging (Indicationonscreen)
The“Aftercharging”phaseisthephasewherethebatteryis
chargeduptoapp.100%ofthefullcapacity.Thevoltageisraised
0.4VcomparedtotheBulkchargingphase.
Testing (Indicationonscreen)
The“Testing”phaseisthephasewherethebatteryistestedfora
defectbatterycell.
Maintenance (Indicationonscreen)
Thepurposewith“maintenance”phaseistokeepthebatteryat
100%capacityoveralongperiodoftime.Thechargerisalways
measuringthevoltageandwhenitgoesbelow12,6/25,2Vitwill
startchargingthebattery.
Boost (Indicationonscreen)
The“Boost”phaseisusedtokick-startthebatteryifithaslow
power.This“Boost”ismadeasanintelligentboosting.Thismeans
thatthechargerisboostingthebatteryfor½hourwithmaximum
currentandthenatestismadeofthebatterytoseeifitisreadyfor
normalcharging.Ifthebatteryisnotreadyfornormalcharging,the
chargerwillboostagain.Thisprocessisrepeated4timesandif
thebatteryisnotOkafterthatthechargerwillindicateafault.
Whilechargingtheactualvoltage,currentandtheselectedbatterytypeisshown
inthedisplay.ItisalsopossibletoseehowmanyAhhasbeenchargedtothe
battery(notthetotalAhonthebattery)Thisisdonebypressingthedownbutton.
ItispossibletostopthechargingbypressingtheBackorSelectbutton.