Note the spark in the spark gap window. It should be
strong and continuous, not intermittent, acrossa preset
8mm(0.32in) gap. Allow the spark to jump the test gap for at
least five minutes continuously. To insure proper operation
under the temperature of actual riding.
Electronic tester
Ignition coil testing lead
Use portable tester to check it.
Test the resistance between igntion ground wire andspark
plug cap.
Ignition coil second resistance12-18 KQ
MAGNETO EXCITING COIL
remove the right frame side cover
disconnect the exciting coil lead wire(black with red
tracer).
Using a pocket tester, measure the resistance between the
B/R lead wire and ground. If the resistance checked is
incorrect, replace the coil.
Exciting coil restance
140-220

Other manuals for KEEWAY HURRICANE

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the KEEWAY HURRICANE and is the answer not in the manual?

KEEWAY HURRICANE Specifications

General IconGeneral
Fuel SystemCarburetor
Front SuspensionTelescopic fork
Front BrakeDisc
Rear BrakeDrum
Height1120 mm
Engine TypeSingle cylinder, 4-stroke
Max Torque9.2 Nm @ 6500 rpm
Cooling SystemAir cooled
TransmissionAutomatic
Fuel Capacity5.5 liters