Item
Description
Note
1
Communication
interface
For service and optional extensions
2
USB charging socket
For charging commercially available USB
devices
3
Connector socket for
start-stop sensor
Optional automatic start/stop.
See chapter "Spare parts and accessories"
4
Signal horn
See also chapter "Troubleshooting"
5
LED signal lamp
Indicates the current operating status
6
Digital LED display
Indicates settings, parameters,
performance values, notes and faults
7
Rotary switch
Switches the product on or off
Settings and queries can be carried out by
turning and pressing the buttons.
Tab. 27: Operating elements
Alarm horn (Pos. 4)
NOTE
Reliable capture of welding fumes is only possible with sufficient extraction
capacity. As the dust load on the filter increases, the flow resistance rises
and the extraction capacity decreases.
As soon as it drops below a minimum value, the signal horn sounds.
If the integrated cleaning system is no longer sufficient, a filter change is
required or the optional cleaning system must be started.
The same happens if the extraction capacity is reduced too much by
closing the extraction hose.
A remedy is to check for blockages.