1502030-00 - 82 -
Display
Description 1
Description 2
Setting
value
DEL
Delay
Automatic start/stop run-on
time
Yes
OPH
Operating hours
Operating hours
HUS
Hours Until Service
Hours until maintenance
dP
delta P
Differential pressure of the filter
(kPA)
dPA
Delta P Airflow
Pressure of the extraction
volume measurement (kPA)
tP
Total pressure
Extraction pipe vacuum (kPA)
CLE
Cleaning processes
Number of cleaning processes
US
1 = US, 0 = Metr.
Displayed units; Metric or US
PFC
Pressure Filter
Cleaning
Shows the filter pressure in
Pa/kPa at which cleaning
occurs automatically
SEC
Service code
Service code
Yes
Tab. 28: Menu
NOTE
Pressure information below 1000 Pa is displayed in Pa.
Pressure information above 1000 Pa is displayed in kPa.
6.2.2 Activation codes
Advanced functions can be activated by entering activation codes.
Activation codes can be entered a maximum of 5 times in succession. A
correct code is signalled by green flashing, an incorrect code by red
flashing of the signal lamp (Pos. 5). If an incorrect code has been entered 5
times in succession, the code entry is blocked for 60 seconds. The menu
item “SEC” cannot be activated then. Any further incorrect entry will then
lock it again for 60 seconds.
6.2.3 Displaying the product ID
To query the three-digit product ID number, press and hold the rotary
switch (Pos. 7) for more than 5 seconds.