EN
4.3 Welding parameters
MIG
WFSpeed 0.7…25 m/min Sets the wire feed speed.
Changes by steps of 0.05, when WFSpeed < 5 m/min,
and by 0.1, when WFSpeed > 5 m/min
WFS-Max Sets the limit for maximum WFSpeed
WFS-Min Sets the limit for minimum WFSpeed
Voltage 8…50 V Step: 0.1 Controls the length of the arc
VoltageMax Sets the limit for maximum voltage value
VoltageMin Sets the limit for minimum voltage value
Dynamics -9…+9 Factory setting is 0 Controls the short circuit behaviour of the arc. The
lower the value the softer the arc is. The higher the
value the rougher the arc is.
1-MIG
WFSpeed 0.7…25 m/min * Sets the wire feed speed.
Changes by steps of 0.05, when WFSpeed < 5 m/
min, and by 0.1, when WFSpeed > 5 m/min
WFS-Max Sets the limit for maximum WFSpeed
WFS-Min Sets the limit for minimum WFSpeed
FineTuning -9…+9 Factory setting is 0
( = curve point)
Adjusts the arc voltage of the curve (arc length)
within certain limits
FineTuningMax -9…+9 Step: 0.5 Sets the limit for maximum arc length
FineTuningMin -9…+9 Step: 0.5 Sets the limit for minimum arc length
Dynamics -9…+9 Factory setting is 0 Controls the short circuit behaviour of the arc. The
lower the value the softer the arc is. The higher the
value the rougher the arc is.
PULSE MIG
WFSpeed 0.7…25 m/min * Sets the wire feed speed.
Changes by steps of 0.05, when WFSpeed
< 5 m/min, and by 0.1, when WFSpeed > 5 m/min
WFS-Max Sets the limit for maximum WFSpeed
WFS-Min Sets the limit for minimum WFSpeed
FineTuning -9…+9 Factory setting is 0
( = curve point)
Adjusts the base current of the curve (arc length) in
certain limits
FineTuningMax -9…+9 Step: 0.5 Sets the limit for maximum arc length
FineTuningMin -9 ... +9 Step: 0.5 Sets the limit for minimum arc length
Dynamics -9…+9 Factory setting is 0 Controls the short circuit behaviour of the arc. The
lower the value the softer the arc is. The higher the
value the rougher the arc is.
Pulse Current -10…+15% Factory setting
is 0 %
Reduces (–) or raises (+) the pulse current of the
curve
FastMig X 450
14