28 Mastertig AC/DC 2000, 2500, 2500W, 3500W/0510
© COPYRIGHT KEMPPI OY
Mains voltage
Rated power
Welding current range
Connection cable
Fuse
Maximum load**)
Fuse
Maximum load***)
Open circuit voltage
Frequency of AC*)
Efficiency
Power factor
Cos fii
Open circuit power
Storage temperature range
Operating temperature range
Temperature class / Degree of protection
External dimensions
Weight
1~ 50 / 60 Hz
TIG max.
TIG 100 %
MMA max.
MMA 100 %
TIG DC
AC
MMA DC
AC
TIG AC 30 % ED (T = 40 °C)
TIG AC 100 % ED (T = 40 °C)
MMA 20 % ED (T = 40 °C)
MMA 100 % ED (T = 40 °C)
TIG AC 50 % ED (T = 40 °C)
TIG AC 100 % ED (T = 40 °C)
MMA 60 % ED (T = 40 °C)
MMA 100 % ED (T = 40 °C)
(AC and DC)
fixed / adjustable
length
width
height
230 V ± 10 %
200 A / 6,8 kVA
150 A / 4,5 kVA
160 A / 7,3 kVA
100 A / 4,2 kVA
3 A / 10 V ... 200 A / 18 V
10 A / 10 V ... 200 A / 18 V
10 A / 10 V ... 160 A / 26,4 V
11 A / 10 V ... 160 A / 26,4 V
3 x 2,5 mm
2
S- 3
16 A delayed
200 A / 18 V
150 A / 16 V
160 A / 26,4 V
100 A / 23,6 V
20 A delayed
200 A / 18 V
150 A / 16 V
160 A / 26,4 V
140 A / 23,6 V
70 V DC
60 Hz / 50 ... 200 Hz
75 % (160 A / 26,4 V)
0,8 (160 A / 26,4 V)
0,96 (160 A / 26,4 V)
18 W
-40 ... +60 °C
-20 ... +40 °C
B (130 °C), H (180 °C) / IP 23C
540 mm
260 mm
510 mm
30 kg
11. TECHNICAL DATA
*) Adjustable with MINILOG- and PULSE panels.
**) Fuse reduces maximum load.
***) Use of 20 A fuse requires changing of connection cable.
The products meet conformity requirements for CE marking.