Measurements
TESTING OF THE POWER STAGE
1. Disconnect cooling fans (A001/X9).
2. Disconnect (HF, Spark generator card) A003/X8.
3. Connect jumpers A001/X14 (overvoltage) and A001/X16 (main switch open) on control card
A001.
4. Remove insulation plate from the top of Z003.
5. Disconnect Z004/X7 and Z004/X6 to A002/X1. Leave X8 connected.
Check again for correct cable !!!
(In older models there is two different pads on Z004, X4 and X6. Disconnect X6)
6. Connect MLS-Service power DC+ (= 560Vdc) to wire connector X6 (goes to A002) and DC- to
Z004/X8 (X6=560V, X8=0V).
7. Connect Kemppi Multipower with 98 Vdc (24+24+50 Vdc in series) between phases L2, L3.
8. Switch on MLS- Service power and check the panel functionality.
9. Switch on Multipower. Turn mains switch on.
10. Set the machine to MMA mode.
11. Measure following voltages (X8 = GND = -Dix) from Z003.
heat sink = + 9 … 11 Vdc
X5 = - 9 … 11 Vdc
X7 = + 62 ... 75 Vdc (refers to DC+ voltage if err 6 is reported)
X9 = - 58 ... 75 Vdc (refers to DC- voltage if err 6 is reported)
If voltages are OK then power stage and rectifier are OK.
12. Switch off machine, Multipower and MLS Service power.
13. Disconnect power supplies.
14. Restore jumpers and wires.