Questions and Answers

  • S
    Shane HayesJul 29, 2025
    Why is the air from my Kenmore 35915 not cold enough?
    • M
      Matthew KlineJul 29, 2025
      If the air from your Kenmore Air Conditioner doesn't feel cold enough, try these solutions: First, check the FAN SPEED and set it to HI. Also, make sure the TEMP Control isn't set too warm; lower the temperature. If the room temperature is below 70°F (21°C), cooling may not occur until the room temperature rises above this. Finally, ensure the temperature sensing tube isn't touching the evaporator coil; straighten it away from the coil.
  • M
    Michael StephensAug 2, 2025
    Why is my Kenmore 35915 cooling, but the room is too warm and ice is forming on the cooling coil?
    • H
      Hannah KnightAug 2, 2025
      If your Kenmore Air Conditioner is cooling, but the room remains too warm and ice is forming on the cooling coil, it could be due to a few reasons. If the outdoor temperature is below 70°F (21°C), set the MODE to FAN to defrost the coil. A dirty air filter can also cause this issue, so clean the air filter. Also, if the temperature control is set too cold for night-time cooling, set the MODE to FAN or 'High Cool' with the TEMP control to a higher temperature to defrost the coil.
  • N
    Noah RayAug 7, 2025
    What to do if my Kenmore Air Conditioner will not operate?
    • G
      George LuceroAug 7, 2025
      If your Kenmore Air Conditioner isn't operating, make sure it's properly plugged into the wall outlet. Check for a blown fuse or tripped circuit breaker and replace or reset it. Ensure the power is on by pushing the power button. If you recently turned it off and on, wait 3 minutes before restarting. Also, check that the temperature control isn't set warmer than the room temperature. Finally, if the current interrupter device is tripped, press the RESET button on the power cord plug. If the RESET button will not stay engaged, discontinue use of the air conditioner and contact a qualified service technician.
  • G
    Garrett SmithAug 11, 2025
    Why is my Kenmore Air Conditioner turning on and off rapidly?
    • T
      Tracey HarrisonAug 11, 2025
      If your Kenmore Air Conditioner is turning on and off rapidly, it might be because the outside temperature is extremely hot. To address this, set the FAN SPEED on HI to increase airflow past the cooling coils.
  • L
    Lisa HansonAug 15, 2025
    Why is there water dripping inside the room from my Kenmore Air Conditioner when it is cooling?
    • S
      sgarzaAug 15, 2025
      If water is dripping inside the room from your Kenmore Air Conditioner while it's cooling, it might be improperly installed. To fix this, tilt the air conditioner slightly to the outside to allow for proper water drainage. Refer to the installation instructions or consult with an installer for assistance.
  • S
    smithwilliamAug 20, 2025
    Why is my Kenmore 35915 Air Conditioner making noise when cooling?
    • B
      benjamin39Aug 20, 2025
      If your Kenmore Air Conditioner is making noise while cooling, it could be due to a couple of reasons. It may be the sound of the fan hitting water from the moisture removal system, which is normal in high humidity. Close doors, windows, and registers to help. Alternatively, it could be window vibration due to poor installation. Refer to the installation instructions or check with the installer.
  • R
    Robert TaylorAug 25, 2025
    Why is water dripping outside when my Kenmore 35915 Air Conditioner is cooling?
    • J
      Jeffrey DuffyAug 25, 2025
      If water is dripping outside when your Kenmore Air Conditioner is cooling, it's likely because the unit is removing a large amount of moisture from a humid room. This is normal during excessively humid days.

Summary

WARRANTY

SAFETY

Important Safety Instructions and Warnings

General precautions, electrical safety, and energy saving tips.

ELECTRICAL REQUIREMENTS

Grounding, Power Cord, and Extension Cord Guidelines

Emphasizes proper grounding, cord use, and avoiding extensions.

INSTALLATION

Installation Requirements and Hardware

Window fit, parts, tools, electrical checks, and handling safety.

Step-by-Step Installation Procedures

Detailed steps from initial setup to bracket attachment.

INSTALLATION

Completing Installation and Drainage

Finalizing window sealing, drainage, and vent adjustments.

Front Grille, Storm Window, and Removal

Attaching front grille, adapting for storm windows, and unit removal.

OPERATION

MAINTENANCE

Filter Cleaning and Unit Cleaning Procedures