SERVICE TECH. INFORMATION
SECTION 5
25
5C. TROUBLESHOOTING
a. If it does not move into fill, valve motor is inop-
erative. Check all wiring and connections.
b. If water does not enter tank, see Quick-Check
Troubleshooting, page 26.
After fill, press ¤ to move
softener into brining. A slow flow
of water to drain begins. Verify
brine draw from brine tank. See
flow rates on page 23.
NOTE: WHILE IN MANUAL ADVANCE, THE
TIME DISPLAY WILL AUTOMATICALLY RE-
TURN TO THE PRESENT TIME IF A BUTTON IS
NOT PRESSED WITHIN 4 MINUTES.
c. If softener does not draw brine¼see Quick-
Check Troubleshooting.
NOTE: Be sure a salt bridge is not preventing water
with salt contact.
Again press ¤to move softener
intobackwash.Lookforafastflow
of waterfrom drainhose. Seeflow
rates, page 23.
d. An obstructed flow indicates a
plugged top distributor, back-
wash flow plug, or drain hose.
Press ¤ to move softener into
fast rinse. Againlookfor fastdrain
flow. Allow softener to rinse for a
few minutes toflushoutanybrine
remaining in resin tank from brin-
ing cycle test.
To return softener to service,
press ¤.
4. Press ¢ to display 18:88.
5. Press £ toreturn present time
and day.
BRINE VALVE FLOAT SETTING FREEBOARD MEASUREMENT
Freeboard*
PM
MO WE TH FR SA
RCHG
.
.
AM
TU
SU
.
.
MO
PM