EasyManua.ls Logo

Kenmore 795.69293.902 - 8-3 SENSOR RESISTANCE SPECIFICATION

Kenmore 795.69293.902
37 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
- 32 -
8-3 RESISTANCE SPECIFICATION OF SENSOR
• The resistance of the SENSOR has a ±5% common difference.
•Temperature of the SENSOR must be stabilized for minimum of 3 minutes before accurate measurement can be
• Measure the F-SENSOR, SUPER FROST SENSOR, R1, R2-SENSOR after disconnect CON5 of PWB ASSY, MAIN.
TEMPERATURE
RESISTANCE OF REFRIGERATOR &
DEFROST SENSOR
VOLTAGE
-20 °C (-4 °F)
77
3.73
-15 °C (5 °F)
60
3.49
-10 °C (14 °F)
47.3
3.22
-5 °C (23 °F)
38.4
2.95
0 °C (32 °F)
30
2.67
5 °C (41 °F)
24.1
2.4
10 °C (50 °F)
19.5
2.14
15 °C (59 °F)
15.9
1.89
20 °C (68 °F)
13
1.66
25 °C (77 °F)
11
1.46
30 °C (86 °F)
8.9
1.27
40 °C (104 °F)
6.2
0.96
50 °C (122 °F)
4.3
0.72
taken.