- 32 -
8-3 RESISTANCE SPECIFICATION OF SENSOR
• The resistance of the SENSOR has a ±5% common difference.
•Temperature of the SENSOR must be stabilized for minimum of 3 minutes before accurate measurement can be
• Measure the F-SENSOR, SUPER FROST SENSOR, R1, R2-SENSOR after disconnect CON5 of PWB ASSY, MAIN.
TEMPERATURE
RESISTANCE OF REFRIGERATOR &
DEFROST SENSOR
VOLTAGE
-20 °C (-4 °F)
77
3.73
-15 °C (5 °F)
60
3.49
-10 °C (14 °F)
47.3
3.22
-5 °C (23 °F)
38.4
2.95
0 °C (32 °F)
30
2.67
5 °C (41 °F)
24.1
2.4
10 °C (50 °F)
19.5
2.14
15 °C (59 °F)
15.9
1.89
20 °C (68 °F)
13
1.66
25 °C (77 °F)
11
1.46
30 °C (86 °F)
8.9
1.27
40 °C (104 °F)
6.2
0.96
50 °C (122 °F)
4.3
0.72
taken.