4.2
Scanning in One Zone (Single Scan)
The transceiver scans using Single Scan all the added channels in the zone where the transceiver starts scanning.
If
a scan starts in the zone where “Single” is configured in Scan Type, Single Scan is executed. Or, if the transceiver migrates
during the scan to the zone where “Single” is configured in Scan Type, Single Scan is executed.
The target channel for scan is either the channel with Scan Add enabled by using KPG-D1/ D1N or the channel with Scan
Add enabled by using the Scan Delete/Add key.
Operating the transceiver
1
Press the Scan key.
The scan starts after a Key Beep A (1 beep) sounds from the transceiver.
The “ ” icon appears and then Revert Channel is displayed.
If “Scan” Displayed
is enabled, “Scan” is displayed.
For portable transceivers, the LED light flashes according to the
configuration of Non-Priority Scan LED in the case of non-priority scan,
and according to the configuration of Priority Scan LED in the case of
priority scan.
Note
The transceiver behaves in the same manner even if the scan is started
by other method. (Refer to Starting the Scan.)
2
Press the Scan key during the scan.
The scan completes after a Key Beep B (2 beeps) sounds from the
transceiver and the “ ” icon disappears.
Menu Zone
+
Zone 1
Channel 1
12 : 34
A
M
Scan
Menu Zone
+
Zone 1
Channel 1
12 : 34
A
M
Note
0
Single
Scan functions only in the zone consisting of channels of the same system. However, Single Scan functions even
when the zone includes Conventional channels of other systems or channels of an LTR Trunking system.
0
If Selected Channel Scan is enabled, the selected channel can be scanned even if the channel is excluded from the
target channels for scan. (Refer to Selected Channel Scan.)
0
For Portable, if the transceiver changes the zone during a Single Scan by using Selector with “Zone Select” configured
and if the new zone is not configured, the “
” icon blinks and the scan pauses.
0
If
another zone is selected during the Single Scan, the transceiver starts the scan according to the configuration in Scan
Type of the selected zone.
4 SCAN
4.2 Scanning in One Zone (Single Scan)
DMR FUNC (K, F)/Ver 2.20 135