Modes | SSB, CW, AM |
---|---|
IF Frequencies | 8.83 MHz, 455 kHz |
Receiver Sensitivity | 0.25 μV (10 dB S/N) |
IF Rejection | >80 dB |
Power Supply | 13.8 V DC |
Image Rejection | More than 70 dB |
Detailed description of the TC5070P presettable counter IC and its timing.
Explanation of the TS-830S VBT and IF SHIFT controls for bandwidth and frequency adjustment.
Procedure for converting the TS-830S (K) to operate on 240V AC.
Schematic diagram of the TS-830S PLL unit.
List of resistors used in the TS-830S, including types, values, and tolerances.
List of capacitors used in the TS-830S, including types, values, and ratings.
List of semiconductor devices and tubes used in the TS-830S.
List of Field Effect Transistors used in the TS-830S.
List of Integrated Circuits used in the TS-830S.
Parts list for the TS-830S Rectifier Unit.
Parts list for the TS-830S RF Unit.
Parts list for the TS-830S AF Unit.
Parts list for the TS-830S PLL Unit.
Parts list for the TS-830S IF Unit.
Parts list for the TS-830S Final Unit.
Exploded view showing rear panel components, connectors, and mounting hardware.
Procedure to adjust the 9V AVR and 3.6V power supply levels.
Procedure to adjust the base current for optimal operation.
Procedure to adjust the carrier level for proper transmission.
Procedure to adjust carrier level in conjunction with VBT settings.
Procedure to check and adjust VFO, RIT, and FIX CH settings.
Procedure to adjust the counter reference oscillator for accurate frequency counting.
Procedure to adjust and check the Voltage Controlled Oscillator (VCO) frequency.
Procedure to adjust the Band Pass Filter (BPF-A) response.
Procedure to adjust the Band Pass Filter (BPF-B) response.
Procedure to adjust the Band Pass Filter (BPF-C) response.
Procedure to adjust the coil packs for optimal performance across bands.
Procedure to adjust the ALC "O" level for correct automatic gain control.
Procedure to balance the mixer stages for optimal signal reception.
Procedure to calibrate the S-meter for accurate signal strength indication.
Procedure to adjust the Noise Blanker (NB) for effective noise reduction.
Procedure to adjust VBT using VBT-1 for variable bandwidth tuning.
Parts list for the VFO-230 Power Supply Unit.
Parts list for the VFO-230 Digital Unit.
Parts list for the VFO-230 Encoder Unit.
List of test equipment needed for VFO-230 adjustments.
Schematic diagram of the TS-830S Counter Unit.
Procedure for adjusting the AT-230's power meter.
Procedure for calibrating the reference power output of the AT-230.