STD PRE and EZ PRE Operation Modes
Version 8.7 of the batcher software allows the user to choose between STD PRE (Standard Preset)
and EZ PRE (Easy Preset) operation modes. STD PRE operation is well suited for batch amounts
that do not change, since the program mode must be entered to change the preset and the batch
count must be cleared before starting a new batch. EZ PRE has been designed for users who
frequently change the batch amount. During EZ PRE operation, the preset can be viewed and
changed without entering the program mode and another batch can be started without resetting the
Before a batch is started and after a batch is complete, the unit will continue to totalize all
EZ PRE is not available on units with 16 Point Linearization.
- Go into the Program Mode and
select STD PRE in the PRE TYP sub menu.
Set the PRESET and PREWARN
Program Mode and enter the desired values for
the PRESET and the PREWARN.
Mode and set up the counter in the COUNT sub
- In the Run Mode, reset the total by
pressing “CLR”, then press “A” to start. When
started, both relays energize and the counter
begins to count. When the batch is complete,
the relays drop out and the unit displays the
amount that was batched (0 if in Set to Preset
- Press “B”, to temporarily stop
process by de-energizing the PRESET and
PREWARN relays. Press start, “A”, to continue
- In the Run Mode, reset the total
and press the start button.
Mode and enter new PRESET and PREWARN
- Go into the Program Mode and
select EZ PRE in the PRE TYP sub menu.
Set the PRESET and PREWARN
Program Mode and enter the desired values
for the PRESET and the PREWARN.
Mode and set up the counter in the COUNT
- In the Run Mode, press “A” to
start. When started, both relays energize and
the counter begins to total. When complete,
the relays drop out and the display fl ashes the
- Press “B”, to temporarily stop
process by de-energizing the PRESET and
PREWARN relays. Press start, “A”, to continue
- Press the start button.
PRESET fl ashing on the display, type a
new number using the keypad. This number
Display Batch Total or Rate
PRESET fl ashing, press “ENT” to place the
PRESET value in memory and use the “C”
button to toggle between the Batch Total and
1-4 STD PRE and EZ PRE Operation Modes
1-4 STD PRE and EZ PRE Operation Modes