5. Afterthat,detachcontrolswitchesofthecooktop.Makesettingbyturningthe
screwinthemiddleofgascockswithasmallscrewdriverinthemannershown
in the following picture. To adjust flow rate screw, use ascrewdriver having
suitabledimension.ForLPG,turnthescrewclockwise.Fornaturalgas,turnthe
screwonetimecounterclockwise.Atlowposition,lengthofnormalflameshould
be6-7mm.Forthelastcontrol,checkoutwhetherflameisopenorclosed.
Settingofyourappliancemaydifferaccordingtothetypeofgascockused.
VENTILATION OF ROOM
The air needed for burning is received from room air and the gases emitted are
given directly in room. For safe operation of your product, good room ventilation
isaprecondition.Ifnowindoworroomtobeutilizedforroomventilationisavailable,
additionalventilationshouldbeinstalled.However,roomhasadooropeningoutside,
itisnoneededtoventholes.
Figure 4 Figure 5
Room size Ventilating opening
Smallerthan5m³ min.100cm²
Between5m³-10m³ min.50cm²
Biggerthan10m³ no need
Inbasementorcellar min.65cm²