EN
43
5. Afterthat,detachcontrolswitchesofthecooktop.Makesettingbyturningthe
screwinthemiddleofgascockswithasmallscrewdriverinthemannershown
in the following picture. To adjust flow rate screw, use ascrewdriver having
suitabledimension.ForLPG,turnthescrewclockwise.Fornaturalgas,turnthe
screwonetimecounterclockwise.Atlowposition,lengthofnormalflameshould
be6-7mm.Forthelastcontrol,checkoutwhetherflameisopenorclosed.
Settingofyourappliancemaydifferaccordingtothetypeofgascockused.
VENTILATION OF ROOM
The air needed for burning is received from room air and the gases emitted are
given directly in room. For safe operation of your product, good room ventilation
isaprecondition.Ifnowindoworroomtobeutilizedforroomventilationisavailable,
additionalventilationshouldbeinstalled.However,roomhasadooropeningoutside,
itisnoneededtoventholes.
Figure 4 Figure 5
Room size Ventilating opening
Smallerthan5m³ min.100cm²
Between5m³-10m³ min.50cm²
Biggerthan10m³ no need
Inbasementorcellar min.65cm²