Risk of death or injury due to a machine in operation!
A machine in operation can pose a risk of death and injury, as well as a risk of
material damage to the machine and system!
• Before any maintenance work can be carried out, the machine must be
disconnected from the power supply and secured against being turned on
again.
The planning, execution and documentation of inspections must be performed in
accordance with all applicable laws and regulations.
In order to ensure a safe operation of the machine, all safety devices must be
checked:
Lubrication points
Personnel:
• Private and commercial operators
Protective equipment:
• Protective workwear
• Protective gloves
• Protective eyewear
• Remove the fan housing every 100 operating hours, or at least once a year -
preferably before the start of the season - and clean the cooling fins, as well
as the baffles, cooling air screen and oil cooler needed for the air circulation.
• Clean the spark plug by removing any soot sediments with a wire brush and
then check the electrode gap. The electrode gap should be approx. 1 mm.
Replace the spark plug after 200 operating hours.