-- System Control Setup Commands: --
-- SPC AS z : Set Auto Sense Mode x = [0=OFF,1=AUTO,2=FORCED ON] --
-- SPC FB E/D : Enable/Disable Front Panel Buttons --
-- SPC CAM z : Set CAMUSB Control Mode z = [0-7] --
-- SPC RSB z : Set USB RS232 Baud Rate to z bps, z=[0-5] --
-- [0:115200, 1:57600, 2:38400, 3:19200, 4:9600, 5:4800] --
-- SPC DF : Reset to Factory Defaults --
-- SPC DF00 : Reset to Factory Defaults without Network Reset --
-------------------------------------------------------------------------
Status Command (STA). Returns unit status and settings in readable format:
-------------------------------------------------------------------------
-- Key Digital Systems STATUS --
-------------------------------------------------------------------------
-- Model: KD-UPS52U, Device Name: KDUPS52U_0001 --
-- Main F/W Ver: 1.00, Splitter Ver: 1.00, CEC Ver: 1.00 --
-- --
-- Service : Baud Rate=115200bps, Data=8bit, Parity=None, Stop=1bit --
-- Front Panel Button : Enabled , CAMUSB Control Mode : 0 --
-- --
-- Network Setting(Web Server/TCP Control) Status --
-- MAC Address = 60:89:B1:36:00:01 --
-- Host IP Address = 192.168.001.239 --
-- Net Mask = 255.255.255.000 --
-- Router IP Address = 192.168.001.001 --
-- TCP Port = 0023 --
-- --
-- Video Input Status --
-- EDID = DEFAULT 10, FORCED HPD = ON , AUTO SENSE = OFF --
-- 01 : HDMI1, LINK = ON --