EasyManua.ls Logo

Keysight Technologies Infiniium MXR Series

Keysight Technologies Infiniium MXR Series
116 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Keysight Infiniium MXR-Series
Real-Time Oscilloscopes
User's Guide

Table of Contents

Questions and Answers:

Keysight Technologies Infiniium MXR Series Specifications

General IconGeneral
BrandKeysight Technologies
ModelInfiniium MXR Series
CategoryTest Equipment
LanguageEnglish

Summary

Notices and Warranty

Technology License

Governs the use and copying of hardware and software described in the document.

U.S. Government Rights

Defines government acquisition rights for commercial computer software.

Safety Notices

Explains CAUTION and WARNING hazard alerts and safe operating practices.

Infiniium MXR-Series Oscilloscopes-At a Glance

Model Specifications

Lists bandwidth and sampling rates for different MXR-Series models.

Key Features

Highlights 10-bit ADC, high resolution, and hardware acceleration.

Oscilloscope Features and Capabilities

Digital Channels and MSO Capabilities

Details MSO functions, digital inputs, and protocol decoding.

Triggering and Protocol Options

Covers various trigger modes and supported protocol analysis.

Built-in Functions (DVM, Waveform Generator)

Describes the digital voltmeter and signal generator features.

User Interface and Hardware Features

Covers front panel, touch screen, storage, ports, and OS.

Measurement and Analysis Tools

Automated Measurements and Analysis

Lists over 50 automated measurements and analysis tools.

Compliance Testing Applications

Lists supported communication protocols for compliance testing.

Guide Overview and Resources

Chapter Summaries

Provides a brief overview of each chapter's content.

Online Help and Support Resources

Guides users to online help, programmer's guide, and contact info.

1 Setting Up

Inspecting Package Contents

Verifies shipment contents and checks for damage.

Environmental Characteristics

Specifies operating and non-operating conditions like temperature and humidity.

Positioning and Airflow

Details airflow clearance requirements for the oscilloscope.

Viewing Adjustments

Explains how to tilt the unit for better visibility using front feet.

Connecting Peripherals and Power

Guides on connecting accessories, LAN, and power sources.

Initial Power-On

Step-by-step instructions for turning on the oscilloscope.

Administrator Password Change

Instructions to enhance security by changing the default password.

2 Getting Started

Oscilloscope Connectors

Identifies front and side panel I/O ports and connectors.

Front Panel Controls

Describes the function of knobs, keys, and buttons on the front panel.

Graphical User Interface (GUI)

Explains the main display elements, menus, and navigation.

Connecting Oscilloscope Probes

Instructions for attaching probes to oscilloscope channels.

Basic Operation Verification

Steps to confirm initial functionality using default and autoscale.

Waveform Acquisition Control

How to start, stop, and single waveform acquisitions.

Adjusting Waveform Display

Guides on setting horizontal and vertical scales and positions.

Triggering and Waveform Generation

Setting up triggers and using the built-in waveform generator.

Data Handling and Analysis

Covers saving, printing, touch screen use, markers, and measurements.

3 Demos and Online Help

Using the Demo Wizard

Introduces the built-in wizard for showcasing oscilloscope features.

Accessing the Online Help

Explains methods to access the software's help system.

4 Other Oscilloscope Tasks

System Settings and Software Installation

Guides on changing OS settings and installing application software.

Maintenance and Recovery Procedures

Covers forcing default setup, hard drive recovery, and cleaning.

5 Calibrating the Oscilloscope

User Calibration Guide

Details when to perform calibration, required equipment, and time.

Calibration Procedure

Step-by-step instructions for performing a user calibration.

6 Testing Performance

Performance Verification Overview

General information on test intervals, records, order, and equipment.

Input Impedance Test

Verifies the input impedance characteristics of the vertical inputs.

Offset Accuracy Test

Measures the accuracy of the vertical offset setting.

DC Gain Accuracy Test

Checks the accuracy of DC gain measurements across channels.

Analog Bandwidth Test

Verifies the instrument's frequency response up to its specified bandwidth.

Time Scale Accuracy (TSA) Test

Measures the accuracy of the oscilloscope's timebase.

7 Troubleshooting

Verifying Basic Operation

Steps to confirm the oscilloscope is functioning correctly after power-up.

Front Panel Control Testing

Guides to test keyboard, LEDs, and touch screen functionality.

System Verification Procedures

Instructions for running user calibration and performance tests.

Support and Service Information

Guidance on contacting support and preparing for service.

Related product manuals