The system starts to count the time once the fan motor operates. The check filter feature can be only activated when the accumulated
operation time achieves 250 hours or more. The Reset light(Clean filter indicator light) flashes at one time per second, after finishing
clean the air filter, press the Filter button and the Reset light(Clean filter indicator light) goes o.
The dehumidifier shuts o when the bucket is full, or when the bucket is removed or not replaced in theproper position.
For some models, the fan motor will continue to run for 30 seconds.
Wait 3 minutes before resuming operation After the unit has stopped, it can not be restart operation in the first 3
minutes.This is to protect the unit. Operation will automatically start after 3 minutes.
Auto Shut O
Check filter feature
If the unit breaks o unexpectedly due to the power cut, it will restart with the previous function setting automatically when the power resumes.
Auto-Restart
When the unit is on, first press the Timer button, the Timer O indicator light illuminates. It indicates the Auto Stop program is initiated. Press it
again the Timer On indicator light illuminates. It indicates the Auto Start is initiated.
When the unit is o, first press the Timer button, theTimer On indicator light illuminates. It indicates the Auto Start program is initiated. Press it
again the
Timer O indicator light illuminates. It indicates the Auto Stop is initiated.
Press or hold the UP or DOWN button to change the Auto time by 0.5 hour increments, up to 10 hours, then at 1 hour increments up to 24 hours.
The control will count down the time remaining until start.
The selected time will register in 5 seconds and the system will automatically revert back to display the previous humidity setting.
When the Auto Start & Auto Stop times are set, within the same program sequence, Timer On O indicator lights illuminate identifying both On
and O times are now programmed.
Turning the unit On or O at any time or adjusting the timer setting to 0.0 will cancel the Auto Start/Stop function.
When LED display window displays the code of P2, the Auto Start/Stop function will also be cancelled.
Setting the Timer
Electronic Work
NOTE: The cographs are for
explanation purpose only. Your
machine may be slightly dierent.
The actual shape shall prevail.
WARNING:
BEFORE PERFORMING ANY ELECTRICAL OR WIRING
WORK, TURN OFF THE MAIN POWER TO THE SYSTEM.
DISPLAY
MAIN
CONTROL
POWER
SUPPLY
CORD
13

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keystone KSTAD504F and is the answer not in the manual?

Keystone KSTAD504F Specifications

General IconGeneral
BrandKeystone
ModelKSTAD504F
CategoryDehumidifier
LanguageEnglish

Related product manuals