ERROR CODES
Error Code
Error type can be read out on the control display
Error 1
Battery protection cut-out
● Please check the source voltage to ensure it is above the cut out.
Try lowering the voltage cut out setting to LOW
● The vehicle cabling may be inadequate/unsuitable. Please refer
to cable specification table for correct cable thickness (Page3)
● Try on a different power source
Error 2
Fan issue
● Fan is drawing too many Amps(Over 1 Amp)
Contact Kickass
Error 3
Compressor Start Issues
● Unplug for 10 minutes
● Try on a different power source
● Possible electronic box or compressor fault
Contact Kickass
Compressor speed is too low
● Unplug for 10 minutes
● Reduce product load inside unit
● Move unit to a lower ambient temperature
● Clean vents/ensure clear air-flow over compressor
Error 4
Ambient Temperature too high
● Clean Vents/ensure clear air flow
Error 5
Thermostat failure
● Check if the NTC thermistor has a short circuit or has
no connection
Error 6/7
13