4
SETUP
GENERAL
Caution! -Humidity inside the appliance can form frost and impair cooling. Do not allow
frost to build up. Never clean the appliance using a hose and never submerge the unit in
any liquid.
Avoid placing your refrigerator near a heat source. This helps the refrigerator to work
more efficiently and keep the contents cool.
Note! - Your refrigerator requires good ventilation, especially around the vents of the
refrigerator; allow a gap of at least 200mm around the vents.
Place the refrigerator on a flat surface and away from any edges. When using the
fridge in a vehicle, please use a fastening device to secure it.
Note! - Water resistant rating IPX4.
Caution! - The appliance can only be connected to one power source at
a time.
Note! - Suitable for camping use.
ELECTRICAL
Power: The electronic control module controls the compressor motor and
includes three stage battery protection. When the input voltage drops below
the minimum, the compressor will cut out; when the voltage rises to the cut-in
value, the compressor will restart automatically.
Battery Protection: The Secop Compressor requires approximately 10.6Volts
(12Volt System). Note: The early warning alarm will sound off every 4 seconds
for 30 minutes before the compressor shuts off. If an alternative power source
is not found, the early warning alarm will sound off every 8 seconds for 30 mins
until the unit has no more power.