Battery Backup
Models i12040ACA and P12040CA with battery backup will not 
function without a properly installed battery. They are equipped with a 
battery lockout feature which prevents the battery door from closing if a 
battery is not installed correctly. See Maintenance section for additional 
information concerning battery installation. 
 
Testing
•  To ensure proper operation of models i12040ACA and P12040CA 
in the battery backup mode, press the Test button, (without the 
AC power connected) for at least 5 seconds or until the alarm 
sounds.
CAUTION: Due to the loudness (85 decibels) of the alarm, always stand an 
arms-length away from the unit when testing.
•  Turn on the AC power. The green LED power indicator should be 
lit when the alarm is operating from AC power. 
•  For all models: Confirm unit operation by pressing the Test 
button again. All interconnected alarms should respond.
•  The smoke alarm is operating once AC power is applied, a fresh 
battery is installed (only for battery backup models i12040ACA 
and P12040CA) and testing is complete. When the smoke alarm 
sensor chamber senses products of combustion, the horn will 
sound a loud (85db) alarm until the sensing chamber is cleared of 
smoke particles.
Alarm Tamper Resist Feature
•  To make the smoke alarm tamper-resistant, a locking pin has 
been provided in the bag with the screws and anchors. Using this 
pin will help deter children and others from removing the alarm 
from the mounting plate. To use the pin, insert it into the hole 
in the side of the alarm after the alarm has been installed on the 
mounting plate (Image 4D).
NOTE: The tamper-resistant pin will have to be removed in order to change 
the battery (models i12040ACA and P12040CA). Use long nose pliers to 
pull the pin out of the hole. It is now possible to remove the alarm from the 
mounting plate. 
2. Installation