EasyManua.ls Logo

KiloVault HLX Series - Inverter and Charger Configuration

KiloVault HLX Series
32 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4 - Operation
It is very important that your battery chargers (solar charge controller, inverter/charger
or AC) can be set to settings appropriate for the HLX & CHLX. If it cannot, please
contact KiloVault Technical Support for guidance.
Also, some chargers just have settings for broad battery types like; flooded, gel, agm
or lithium. Before using these chargers on your battery, please contact KiloVault
technical support for guidance.
Note: If you cannot find a specific setting, remember to check the settings for
guidance. Also, please don’t hesitate to contact KiloVault technical support for help.
Voltages are per HLX in a single series string. Amperages are per total HLX strings in
parallel.
Adjust your settings as necessary until your system best fits your power use patterns
and needs.
4.1 - Inverter/Charger Settings
Setting
Values - Volts are per battery in a single
string, Amps are per string in parallel
1200 - Battery Capacity
1200 Wh. 100 Ah
1800 - Battery Capacity
1800 Wh. 150 Ah
3600 - Battery Capacity
3600 Wh, 300 Ah
1200 - Max Charge Current
80 A
1800/1600 Max Charge Current
150 A
Absorb End Amps
2 A
Absorb Time (some controllers do not allow a
selection under 6 minutes, please contact
KiloVault for additional information)
2 minutes or less
Absorb Voltage
14.1 V
KiloVault
®
LLC • 330 Codman Hill Road, Boxborough, MA 01719 • +1 (888) 218-5924 • info@kilovault.com www.kilovault.com