FINAL INSTALLATION
0
1 POSITIONING AND ANCHORING DISHWASHER
DOOR SPRING BRACKET
FIG. 8
Check the upper rear portion of the cabinet opening to make certain that
area is cleared of cabinet or top support framing members. Set the dish-
washer adjacent to cabinet and adjust the four eveling feet to the desired
height. The four leveling feet can be used to raise the dishwasher to 35” or
lower to 33-11/16” (33-7/16” if leveling screws are removed). Adjust
kickplate. Kickplate can be adjusted by moving up or down. After the
dishwasher is in position, make sure it is level from side to side and front
to rear. If possible, dishwasher front should be parallel to counter top and
flush with cabinets. To maintain alignment of dishwasher with adjacent
cabinets, position the L shaped adjustable brackets (furnished at the upper
left and right corners of the dishwasher) per Fig. 8 and fasten the dish-
washer to the counter top with two #lO flat head wood screws (not fur-
nished). When dishwasher is not installed beneath a continuous counter
top it may be necessary to anchor dishwasher to floor using l/4” lag bolt
or screw, in hole provided. If door tension adjustment is required, adjust
door spring so the door is counterbalanced and will remain in open
position. Adjust tension by changing bracket (Fig. 8) to alternate holes
and/or moving spring hooks to alternate position.
0
2
CONNECTING HOT
WATER SUPPLY LINE
Make certain fill line has been flushed clear of foreign
materials. Use compression ell (not furnished) to con-
nect l/2” O.D. copper fill line to dishwasher fill valve.
Make sure fill line has no sharp bends (5” minimum
bend radius suggested) that may produce kinks which
might restrict water flow. Connect fill line to meet local
plumbing codes.
0
3
CONNECTING
DRAIN LINE
Connect dishwasher drain to meet local
plumbing code. See suggested installations
Fig. 5. See note for available drain acces-
sories.
0
CONNECTING ELECTRICAL
4 POWER SOURCE
WARNING: BE SURE ELECTRICAL POWER IS TURNED OFF
AT CIRCUIT BREAKER.
- GROUNDING INSTRUCTIONS -
This appliance must be connected to a grounded metal, permanent,
wiring system; or an equipment-grounding conductor must be run
with the circuit conductors and connected to the equipment-ground-
ing terminal or lead of the appliance.
A - Remove junction box from dishwasher. B - Install approved
strain relief bushing (not furnished). C - Connect power cable white
lead to white lead and black lead to black lead with adequate insula-
tion or wire nuts and ground wire under green ground screw or lug.
Reinstall junction box.
When house wiring is aluminum, use UL listed aluminum to copper
connectors.
FIG. 9
-5-