Document No.:KE-4010-11 Page: 28/58
④ Leaktestshouldbedoneafter15minuitsto30minutspastsincepressurizingactuators.Ifnot,internalair
residueremainsandtheleaktestcannotbedonewithaccuracy.
⑤ Wipeoffallsoapsolutionafterwards.
Ifany leakagehas been detected,disassembletheactuator againto checkif any part or componentis
scratched,deformedorworn,andreplacethem,ifnecessary,withKITZgenuineparts.
(11)Plugtheleakdetectorholewithasealwasherandahexagonheadedbolt,tocompletereassemblyofan
actuator(Fig.19).
(12)MountanindicatorplateontopofthehousingwithtwoheadedscrewssothatMark[O]maypoint(a)the
left-hand of the housing for ball valves, or(b)theair inlet/outletportsforbutterfly valvesas shown in
Fig.20. Aftercheckingcorrectmountingoftheindicatorplate,assembleapositionindicatorthroughthe
shaftsecurelywithasnapring.
Fig.19
Fig.20
(13)Checktrouble-freeoperationofreassembledactuatorsandmountthemonvalves.
21.4Bolttighteningtorques
Allboltsandscrewsshallbesecurelytightenedwiththetorquesrecommendedbelow:
Recommendedbolttighteningtorques [N・m ]
Actuatorsize FA/FAS-1 FA/FAS-2 FA/FAS-3 FA/FAS-4 FA/FAS-5 FA/FAS-6
Piston/
rackassembly
M5; 2〜3 M5; 2〜3 M6; 4〜5
M10; 17〜20 M12; 29〜34 M16; 71〜84
Endcover/
springcover
mounting
M6; 4〜5 M8; 9〜10 M10; 17〜20
M10; 17〜20 M12; 29〜34 M16; 71〜84
Opening range
adjusterbolt
M6; 3〜5 M8; 5〜8 M10; 9〜15
M12; 25〜30 M16; 40〜50 M20;100〜120
Leak detector
holeplugging
M5; 2〜4
Airinlet/outlet
Forballvalves
Airinlet/outlet
Forbutterflyvalves
Indicator<97>
Indicatorplate<98>
Snapring<48B>
Headedscrew<39>
Sealwasher<155B>
Hexagonheadedbolt<13B>