Document No.:KE-4010-11 Page: 47/58
5. 90°TurnofActuator-to-ValveMountingOrientation
Theactuatormountingorientationwithavalvemaybeturnedby90°forlocalpipingconvenienceoroperation
ease. Inthiscase,apositionindicatormustberelocatedsothat[O]indicationbecomesparalleltotheaxisof
thepipingorthedirectionoffluidflow. Anpositionindicatormustbealsorelocatedaccordingtothenew
locationoftheindicatorplateandthevalveopeningposition(Fig.5). Followtheproceduresprovidedbelow.
Standardindicatorplateorientation90°turnedorientation
Fig.5
(1)Mountanactuatoronavalvewithyourdesiredorientationbyturning90°.
(2)Loosenasnapring(withsnapringpliers),andremoveapositionindicatorfromtheshaft.
(3)Relocatetheindicatorplateontopoftheactuatorsothat[O]indicationbecomesparalleltotheaxisofthe
pipingorthedirectionoffluidflow.
(4)Mountthepositionindicator,correctlymatchingtothenewlocationoftheindicatorplateandthevalve
openingposition. Securelyfixitwithasnapring.