Document No.:KE-4010-11 Page: 48/58
6. ActuationofKITZ3-wayBallValves
KITZ3-wayballvalvesmaybeoperatedwithFSeriespneumaticactuatorsbymeansofaddingspecialposition
indicators to the standard one as instructed below ( Fig.6 and Fig.7 ). The position indicator plate is not
neededforactuationof3-wayballvalves.
Fig.6
Fig.7
(1)Loosenasnapring(withsnapringpliers)andremoveapositionindicatorandanindicatorplatefromthe
housing.
(2)AddonespecialindicationmarktoLportdesign,ortwospecialindicationmarkstoTportdesign. These
specialindicationmarksareoptionallyavailable. RefertoTable6forproductcodesofindicationmarks.
Table6.Productcodeofindicationmarks
*Yellowmarksareforredpositionindicators. Blackmarksareforyellowpositionindicators.
(3) Mount the position indicator on the shaft of an actuator, following the valve opening direction. The
indicatorplateisnotneededforoperationof3-wayballvalves.
Actuator Color* Productcode
FA/FAS-1〜 4 Yellow
AD14-4001-B0
FA/FAS-1〜 4
Black AD14-4002-B0
Indication
marks
FA/FAS-5,6
Black AD14-4602-20
PositionIndicator
Indicatorplate
Specialindication
marks
forTportdesign/forLportdesign