Document No.:KE-4010-11 Page: 55/58
8.4.2Adjustmentofvalveopeningrange
(1) Equalizethehousingpressurewiththeatmosphericlevel.
(2)Loosenahexagonnutandrotatethestopperwithaspannertoadjustthevalveopeningrange(Fig.18).
(3)Ensuretosecurelyretightenthehexagonnutafterwards(Fig.18).
 Fig.18
Fig.19
(4) Supply the actual operating pressure to the housing through Port [O] and check external air leakage
throughthecontactofaFSWunitwiththehousing(Fig.19).
8.5DisassemblyofFSWmanualoperatorunit
(1)Disassembletheairtubingandequalizethehousingpressurewiththeatmosphericlevel.
(2)Disassembletheunitfromthehousing(Fig.20).
 Fig.20
 Fig.21
(3)Removeahandwheel,aguide,asetscrew,anutandasealwasherfromtheunit
(Fig.21).
Hexagonnut<123B>
Stoppe
r
Handwheel
Setscrew
Nut
Sealwasher
Guide