Caution: The safety distance between the hotplate and the cupboard above the hotplate
should be at least 760mm.
A (mm) B (mm) C (mm) D E
760 50 mini 20 mini Luftzugang Luftabzug
Before you install the hob, make sure that
the work surface is square and level, and no structural members interfere with space requirements
the work surface is made of a heat-resistant material
if the hob is installed above an oven, the oven has a built-in cooling fan
the installation will comply with all clearance requirements and applicable standards and regulations
a suitable isolating switch providing full disconnection from the mains power supply is incorporated in the
permanent wiring, mounted and positioned to comply with the local wiring rules and regulations.
The isolating switch must be of an approved type and provide a 3 mm air gap contact separation in all
poles (or in all active [phase] conductors if the local wiring rules allow for this variation of the requirements)
the isolating switch will be easily accessible to the customer with the hob installed
you consult local building authorities and by-laws if in doubt regarding installation
you use heat-resistant and easy-to-clean finishes (such as ceramic tiles) for the wall surfaces surrounding
the hob.
the power supply cable is not accessible through cupboard doors or drawers
there is adequate flow of fresh air from outside the cabinetry to the base of the hob
if the hob is installed above a drawer or cupboard space, a thermal protection barrier is installed below the
base of the hob
the isolating switch is easily accessible by the customer