Notes on Refrigerant R290
Warning
The air conditioner must be kept and transported upright. Otherwise, irreparable
compressor damage may occur. Let the unit sit for at least 24 hours before using it.
Switch off the device and disconnect it from the power supply before cleaning.
Make sure that the product generates a constant ow of air. Make sure the air inlets
and outlets are not blocked.
To prevent leaks, operate this unit on a horizontal surface.
Any person working on a refrigerant circuit should have a current certicate from
an accredited assessment body. This ensures competence for the safe handling of
refrigerants according to an industry-recognised assessment specication.
If the device stops working, dispose of it properly.
Store the device in a well-ventilated place when not in use.
Store the device so that it is not damaged.
Repairs may only be carried out by the manufacturer or an authorised specialist
company.
The cables connected to the device may contain potential ignition sources.
Do not damage any components of the refrigerant circuit. Escaping refrigerant may
not be noticed because it is odourless.
Maintenance and repairs must be carried out under the supervision of specialists in
the use of ammable refrigerants.
Information for rooms with refrigerant pipes
Limit the piping to a minimum.
Be careful not to damage the piping.
Appliances with ammable refrigerants may only be installed in a well-ventilated
room.
Comply with national gas regulations.
All mechanical connections must be freely accessible for maintenance purposes.
Information for rooms with refrigerant pipes
Limit the piping to a minimum.
Be careful not to damage the piping.
Appliances with ammable refrigerants may only be installed in a well-ventilated
room.
Comply with national gas regulations.
All mechanical connections must be freely accessible for maintenance purposes.
DANGER
Fire hazard !
This device contains the ammable refrigerant R290. If the refrigerant
escapes and is exposed to an external ignition source, there is a risk
of re.