ENGLISH
OPERATING INSTRUCTIONS
AC VOLTAGE (LESS THAN 1000V)
1. Insert RED test lead into VΩ jack
5
, and BLACK test lead into
COM jack
4
, and rotate function selector switch
2
to the
AC voltage
V
setting.
2. Apply test leads to the circuit to be tested to measure voltage.
The meter will auto-range to display the measurement in the
most appropriate range.
DC VOLTAGE (LESS THAN 1000V)
1. Insert RED test lead into VΩ jack
5
, and BLACK test lead into
COM jack
4
, and rotate function selector switch
2
to the
DC voltage
V
setting.
2. Apply test leads to the circuit to be tested to measure voltage.
The meter will auto-range to display the measurement in the
most appropriate range.
NOTE: If "" appears on the LCD, the test leads are being applied to
the circuit in reverse. Swap the position of the leads to correct this.
NOTE: When in a voltage setting and the test leads are open,
readings of order mV may appear on the display. This is noise and
is normal. By touching the test leads together to close the circuit
the meter will measure zero volts.
Black lead Red lead
Black lead Red lead

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Klein Tools CL600 and is the answer not in the manual?

Klein Tools CL600 Specifications

General IconGeneral
CertificationCE
Clamp opening35 mm
Product colorBlack, Orange
International Protection (IP) codeIP40
Resistance (max)60 Ω
Measuring categoryCAT III 1000V, CAT IV 600V
Carrying caseYes
Battery typeAAA
Number of batteries supported2
Operating altitude0 - 2000 m
Weight and Dimensions IconWeight and Dimensions
Depth97 mm
Width231 mm
Height39 mm
Weight335 g