DC Current Measurement
Range Resolution Accuracy
400µA ~ 400mA
0.1µA
˜
0.1mA
˜
0.1mA
˜
± (1.0% + 5 digits)
4A ~ 10A
1mA
˜
10mA
˜
10mA
˜
± (1.5% + 5 digits)
Overload Protection:
uAmA Input:
400mA (F 440mA / 1000V fuse)
A Input:
10A (F 11A / 1000V fuse)
AC Current Measurement
Accuracy
Range Resolution 40Hz ~ 400Hz 400Hz ~ 10kHz
400
µ
A ~ 400mA
0.1
µ
A
˜
0.1mA
˜
0.1mA
˜
± (1.2% + 5 digits)
± (2.0% + 5 digits)
4A ~ 10A
1mA
˜
10mA
˜
10mA
˜
± (1.8% + 5 digits)
± (2.5% + 10 digits)
Overload Protection:
uAmA Input:
400mA (F 440mA / 1000V fuse)
A Input:
10A (F 11A / 1000V fuse)
Frequency:
40Hz to 10kHz
Response:
True RMS
Resistance Measurement
Range Resolution Accuracy
400
~ 4M
0.1
˜
0.001M
˜
0.001M
˜
± (1.0% + 5 digits)
40M
0.01M
± (1.5% + 10 digits)
Overload Protection:
600V RMS
Capacitance Measurement
Range Resolution Accuracy
40nF
0.01nF
± (3.5% + 6 digits)
400nF ~ 4000µF
0.1nF
˜
1µF
˜
1µF
˜
Overload Protection:
600V RMS
Frequency Measurement
Range Resolution Accuracy
9.999Hz ~ 999.9kHz
0.001Hz
˜
0.1kHz
˜
0.1kHz
˜
± (0.1% + 3 digits)
Overload Protection:
600V RMS
Sensitivity:
0.7V RMS
Duty Cycle Measurement
Range Resolution Accuracy
0.1 ~ 99.9%
0.1%
± (0.2% per kHz + 0.1% + 5 digits)
Overload Protection:
600V RMS
Frequency Range:
0.5Hz to 100kHz, pulsewidth
>
2µsec
Temperature Measurement
Range Resolution Accuracy
-58 ~ 1832°F
0.1 ~ 1°F
± (3.0% + 5.4°F)
-50 ~ 1000°C
0.1 ~ 1°C
± (3.0% + 3.0°C)
Overload Protection:
600V RMS
Thermocouple Accuracy:
Not specifi ed

Related product manuals