Type | Digital Multimeter |
---|---|
Brand | Klein Tools |
Model | MM2000 |
AC Voltage | 600V |
DC Voltage | 600V |
AC Current | 10A |
DC Current | 10A |
Resistance | 40MΩ |
Frequency | 10MHz |
Safety Rating | CAT III 600V |
Continuity | Yes |
Diode Test | Yes |
Auto Ranging | Yes |
True RMS | Yes |
Auto Power Off | Yes |
Low Battery Indicator | Yes |
Data Hold | Yes |
Backlight | Yes |
Display | LCD |
Battery | 2 x AAA |
Details on operating altitude, humidity, temperature ranges, dimensions, weight, calibration, and CAT rating.
Crucial safety instructions to prevent severe injury or death when operating the meter.
Key symbols used in the manual and on the meter for various measurements and indicators.
Explanation of symbols displayed on the LCD screen, including measurement types and status indicators.
Device powers off after 30 minutes non-use; can be woken by dial/button.
Used to switch between AC/DC, resistance, Hz/%, and temperature units.
Stores current value to show difference between stored and live readings.
Allows cycling through manual ranges or returning to auto ranging mode.
Saves largest and smallest values; press to alternate between max and min readings.
Holds current reading on display; press for 2 seconds to enable/disable lights.
Guides on replacing batteries when indicator appears and fuse types.
Optional accessory for hands-free use; slides into rubber boot.
Shows analog representation of measurement, responds faster than digital display.
Instructions for measuring AC/DC voltage, including Low Z mode.
Instructions for measuring large AC/DC current up to 10A.
Instructions for measuring small AC/DC current up to 400mA.
Instructions for measuring resistance, capacitance, testing diodes, and continuity.
Details continuity testing, including resistance display and buzzer sound.
Instructions for measuring frequency and duty cycle up to 1MHz.
Instructions for measuring temperature using thermocouple, Fahrenheit/Celsius ranges.
How to test fuses and interpret 'O.L.' indication.
Specifications for DC voltage ranges, resolution, overload protection, and input impedance.
Specifications for AC voltage ranges, resolution, overload protection, input impedance, and frequency response.
Specifications for DC current ranges, resolution, and overload protection.
Specifications for AC current ranges, resolution, overload protection, and frequency response.
Specifications for resistance ranges, resolution, and overload protection.
Specifications for capacitance ranges, resolution, and overload protection.
Specifications for frequency measurement range, resolution, overload protection, and sensitivity.
Specifications for duty cycle measurement range, resolution, overload protection, and frequency range.
Specifications for temperature measurement range, resolution, and thermocouple accuracy.
Overload protection, test current, open circuit voltage, and range for diode testing.
Overload protection and open circuit voltage for continuity testing.
Details the two-year limited warranty, coverage, and claims process.
Guidance on cleaning the instrument and proper storage procedures.
Information on the proper disposal and recycling of the equipment.
Contact information for customer service and support.