EasyManuals Logo

Klein Tools MM420 User Manual

Klein Tools MM420
16 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #3 background imageLoading...
Page #3 background image
3
ELECTRICAL SPECIFICATIONS
VOLTAGE (AUTO-RANGING)
Function Range Resolution Accuracy
AC Voltage
(V AC)
4.000V 1mV
±(1.0% + 3 digits)40.00V 10mV
400.0V 100mV
600V 1V ±(1.2% + 5 digits)
DC Voltage
(V DC)
400.0mV 0.1mV
±(0.5% + 5 digits)4.000V 1mV
40.00V 10mV
400.0V 100mV ±(0.8% + 3 digits)
600V 1V ±(1.0% + 3 digits)
Input Impedance: 10MΩ
Frequency Range: 50 to 400Hz
Maximum Input: 600V AC RMS or 600V DC
CURRENT (AUTO-RANGING)
AC Current
(μA and mA)
400.0μA 0.1μA
±(1.0% + 5 digits)
4000μA 1μA
40.00mA 10μA
400.0mA 100μA
4.000A 1mA ±(2.0% + 3 digits)
10.00A 10mA ±(2.0% + 5 digits)
DC Current
(μA and mA)
400.0μA 0.1μA
±(1.0% + 5 digits)
4000μA 1μA
40.00mA 10μA
400.0mA 100μA
4.000A 1mA
±(2.0% + 5 digits)
10.00A 10mA
Overload Protection: 500mA / 600V and 10A / 600V Fuses
Frequency Range: 50 to 400Hz
Maximum Input: µA/mA setting: 400mA AC RMS / DC
10A setting: 10A AC RMS / DC
RESISTANCE (AUTO-RANGING)
Range Resolution Accuracy
400.0Ω 0.1Ω
±(1.2% + 5 digits)
4.000kΩ
40.00kΩ 10Ω
400.0kΩ 100Ω
4.000MΩ 1kΩ
40.00MΩ 10kΩ ±(2.0% + 10 digits)
50.0MΩ 0.1MΩ ± ( 2.8% + 10 digits )
Maximum Input: 600V DC or 600V AC RMS
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com